Quadscan4000 Specifications

  • Extracellular Water percentage and Extracellular Water Volume*
  • Intracellular Water percentage and Intracellular Water Volume*
  • Total Body Water percentage and Total Body Water*
  • 3rd Space Water*
  • Body Cell Mass (BCM)*
  • Extracellular Water/Total Body WaterNutrition Index*
  • Plus Normal percentage Levels
  • Body Fat percentage and Fat Weight*
  • Lean Mass *
  • Dry Lean Mass *
  • Basal Metabolic Rate (BMR)*
  • BMR/Total Weight
  • Average Daily Calorie Requirement*
  • Waist/Hip Ratio
  • Body Mass Index – Plus Normal Range
  • Body Fat Mass Index (BFMI)*
  • Fat-Free Mass Index (FFMI)*
  • Prediction MarkerTM (Impedance Ratio)
  • Impedance Values at 5, 50, 100 and 200 kHz
  • Resistance 50 kHz
  • Reactance 50 kHz
  • Phase Angle 50 kHz

*Estimated

  • Multi-frequency Bioelectrical Impedance unit with Bluetooth for PC communication
  • Segmental measurements possible using Prediction MarkerTM (Impedance Ratio)
  • Safe and non-invasive
  • Easy to use
  • Lightweight and portable
  • Quadscan Platinum Software
  • Calibrator for self testing hardware
  • Test results available within seconds
  • Battery operated
  • High contrast, 2 line LCD display
  • Automatic 100 test counter
  • Subject data recall
  • Actual results & recommended ranges
  • Low battery alarm system
  • 12 month parts and labour warranty on a return to factory basis
  • Accepts metric or imperial units
  • Quality Clearance: CE 0120 Medical Devices Directive and FDA
  • Available in English, French, German, Portuguese, Czech and Spanish
  • Non-invasive Bioelectrical Impedance Analysis, Body Composition assessment
  • Non-invasive assessment of hydration and nutrition status
  • Assess Nutritional Status of patients on admission and pre/post-surgery
  • Monitor the Prediction MarkerTM (Impedance Ratio) during hospitalisation – without the need to weigh the patient and irrespective of gender, age, weight, population group
  • Monitor Lean Body Mass, rather than Total Body Weight to determine the patient's response to nutritional supplements
  • Determine if weight gain is due to increase in Lean Body Mass or fluid retention
  • Test can be performed at the bedside, versus other more cumbersome and expensive methods
  • Quick corrective action can be taken to improve the health of the patient
  • Ease of use allows for regular monitoring of status as frequently as required (minutes, hours, days, etc)
  • Fast, reliable, cost-effective, reproducible results
  • Far more informative than Body Mass Index (BMI) which does not distinguish between fat and muscle
  • Number of measurement parameters can be selected to meet specific needs
  • Trend graphs with Quadscan Platinum Software, available for quick evaluation for remedial action
  • Exact time of measurements recorded by Real Time Clock
  • Multi Frequency Bioelectrical Impedance Analysis Unit
  • Comprehensive Hardware User's Guide
  • Cable Leads
  • 120 Disposable Long Electrodes (30 tests)
  • Calibrator
  • Duracell Batteries AA (6)
  • Bodystat®Platinum Software
  • (No Annual Licence Fee) with free telephone/e-mail software support
  • Bluetooth module fitted to download stored test data into a PC
  • Customised Padded Shoulder Bag
  • Pictorial laminated Quick Guide
  • 12 parts and labour warranty on a return to factory basis (excludes lead wires)
  • Bodystat devices use PSoC electronic technology on all our devices (excluding the Touch Screen devices).
  • Programmable Solutions on Chip – the latest technology from Siemens
  • 90% of conventional components replaced by a single PSoC chip
  • Hardware devices are far more reliable electronically than ever before
  • PSoC is highly accurate

    • accuracy of raw data of Impedance values is fully assured
    • ensures high level of precision of hardware devices
    • and reproducibility of measurement results
  • Minimum electronic components to reduce faults
  • Reduces the risk of component failure to the absolute minimum and hence potential repairs to hardware devices
  • Conventional BIA systems CALCULATE Phase Angle . This relies on some assumptions and unknown values and is therefore no more than an estimate of the real value. Bodystat systems directly MEASURES the Phase Angle (Bodystat 1500MDD and Quadscan 4000 devices only) and is calibrated against a known value.
  • Independent certification is supplied for each device as to the accuracy of Phase Angle measurement

BIAS Platinum Windows Software Program

Included with your QuadScan 4000 device, the BIAS Platinum Software Program. BIAS Body Manager Pro Software program includes the following reports:
~ Onscreen graphs and printouts on the subject's body composition, hydrational, cellular health and BIVA results; ~ Body Composition Professional Report;
~ Email reports immediately at the touch of a button in a variety of formats including pdf, xlsx, csv and many more; ~ Hydrational Report;
~ Results are downloaded ensuring data integrity protection; ~ Health Report (Cardiac Risk);
~ Export input and result data to Excel, xml or csv; ~ Weight Loss Report ;
~ Group filter to allow easy analysis of results; ~ Physiology Report;
~ Ability to key in other physiological measurements; ~ Advanced Report;
~ Alternative Equations for COPD, Competitive Athletes, Children and Geriatric. ~ Trending graphs available on screen.

Quadscan4000 Touch Screen Specifications

  • Body Fat percentage and Fat Weight*
  • Lean Mass *
  • Dry Lean Mass *
  • Total Body Water percentage and Total Body Water*
  • Normal percentage Levels
  • Fat Free Mass Index (FFMI)*
  • Body Fat Mass Index (BFMI)*
  • Extracellular Water percentage and Extracellular Water Volume*
  • Intracellular Water percentage and Intracellular Water Volume*
  • 3rd Space Water*
  • Body Cell Mass (BCM)*
  • Basal Metabolic Rate (BMR)*
  • BMR/Total Weight
  • Average Daily Calorie Requirement*
  • Waist/Hip Ratio
  • Nutrition Index*
  • Body Mass Index – Plus Normal Range
  • Prediction MarkerTM (Impedance Ratio)
  • BIVA (Bioimpedance Vector Analysis)
  • 11 Impedance Values from 5kHz to 200 kHz
  • Resistance
  • Reactance
  • Phase Angle

*Estimated

  • Multi-frequency Bioelectrical Impedance unit with Wifi Interface
  • Segmental measurements possible using Prediction Marker (Impedance Ratio)
  • Safe and Non-invasive
  • Easy to use
  • Lightweight and portable
  • BIAS Platinum software
  • Test results available within seconds on-screen
  • Medical Grade Rechargeable Battery
  • High contrast, colour touch screen
  • Pop-up on-screen alpha-numeric keyboard to key in data directly into device
  • Device can store up to 1000 tests
  • Subject data recall
  • Actual results & recommended ranges
  • Low battery alarm system
  • 12 month parts and labour warranty on a return to factory basis
  • Accepts metric or imperial units
  • Quality Clearance: CE 0120 Medical Devices Directive and FDA
  • Available in English, French, Italian, Czech, German, Portuguese and Spanish
  • Non-invasive Bioelectrical Impedance, Body Composition Analysis assessment
  • Non-invasive assessment of hydration and nutrition status
  • Assess Nutritional Status of patients on admission and pre-surgery
  • Monitor the Prediction MarkerTM (Impedance Ratio) during hospitalisation – without the need to weigh the patient and irrespective of age, weight, population group
  • Monitor Lean Body Mass, rather than Total Body Weight to determine the patient's response to nutritional supplements
  • Determine if weight gain is due to increase in Lean Body Mass or fluid retention
  • Multi Frequency Bioelectrical Impedance Analysis Unit
  • Comprehensive Hardware User's Guide
  • Set of screened lead wires (one pair)
  • 120 Disposable Long Electrodes (30 tests)
  • Calibrator
  • Medical Grade battery charger unit
  • Rechargeable battery pack (pre-installed)
  • Bodystat BIAS Platinum software
  • (No Annual Licence Fee) with unlimited Telephone/E-mail Software Support
  • Wifi to connect with PC windows software
  • Branded Padded Shoulder Bag
  • Pictorial User's Quick Guide
  • 12 month parts and labour warranty on a return to factory basis (excludes lead wires)
  • Calibration Certificate
  • Conventional BIA systems CALCULATE Phase Angle. This relies on some assumptions and unknown values and is therefore an estimate of the real value.

Bodystat systems directly MEASURE the Phase Angle and is calibrated against a known value.

  • Independent certification is supplied for each device as to the accuracy of Phase Angle measurement

BIAS Platinum Software Program

Included with your QuadScan 4000 device, the BIAS Platinum Software Program. BIAS Platinum Software program includes the following reports:
~ Onscreen graphs and printouts on the subject's body composition, hydration, cellular health and BIVA results; ~ Body Composition Professional Report;
--- ---
~ Email reports immediately at the touch of a button in a variety of formats including pdf, xlsx, csv and many more; ~ Hydration Report;
~ Results are downloaded ensuring data integrity protection; ~ Health Report (Cardiac Risk);
~ Export input and result data to Excel, xml or csv; ~ Weight Loss Report ;
~ Group filter to allow easy analysis of results; ~ Physiology Report;
~ Ability to key in other physiological measurements; ~ Advanced Report;
~ Alternative Equations for COPD, Competitive Athletes, Children and Geriatric. ~ Trending graphs available on screen, including BIVA trends.

Touch Screen features:

Built-in on-screen alpha-numeric keypad to type in patient’s name and input hospital reference data.

Differences between the Quadscan4000 and the Quadscan4000 Touch Screen:

Quadscan Quadscan Touch
LCD screen Colour Touch Screen
4 frequencies (5-200kHz) 11 frequencies (5-200kHz)
Battery operated Rechargeable battery charged in mains
Device stores 100 tests Device stores 1000 tests
On-screen quality check impedance curve
On-screen alpha-numeric keyboard to enter subject name and input hospital reference data
BIVA (vector analysis) graph visible on screen
Body Composition and Hydration chart visible immediately on screen
Built in PC

Clinical Applications for the QuadScan4000

BURNS – Large changes in body fat mass during the treatment of major burns injuries.

CANCER – Improving nutrition before surgery can decrease post-operative complications and length of stay.

CARDIOVASCULAR DISEASE – Excessive fluid accumulation is associated with increased morbidity and prolonged convalescence after cardiopulmonary bypass.

COPD – Fat-free mass is an independent predictor of mortality irrespective of fat mass...supports the inclusion of body-composition assessment as a systematic marker of disease severity in COPD staging.

CRITICALLY ILL PATIENT – Critically ill patients retain fluid, up to 30 litres and more.

DIABETICS – Overweight and obesity are associated with the development of type 2 diabetes. Thus, it is important for clinicians to accurately measure and monitor the body composition of at-risk individuals and patients with diabetes.

DIALYSIS/NEPHROLOGY – As renal function declines salt & water retention worsens resulting in an increase in body weight due to an increase in water content.

DRUG DOSING – ''... the calculation of lean body mass (LBM) might be an important factor when determining drug doses as opposed to total body weight. This may avoid giving overweight patients a relative overdose of herapin..''

EATING DISORDERS – Bulimic patients with a past had lower percentage of body fat, lower muscle mass and higher percentage of extra-cellular fluid.

ELDERLY – Improved estimation of body composition in elderly subjects by use of age-specific prediction equations.

HIV/AIDS – Body composition testing can be used to monitor lipodystrophy and wasting, two problems associated with HIV.

HYDRATION STATUS/FLUID RETENTION – Measurement of extra-cellular and total body water provides useful information on the nutritional status of surgical patients and may be estimated

LYMPHEDEMA – Early intervention will reduce the long term consequences of Lymphedema post breast cancer.

MALNUTRITION/UNDERNUTRITION/NUTRITION – Malnutrition results in a loss of body cell mass (BCM) accompanied by an expansion of the extra-cellular mass (ECM).

NEONATES – Bioelectrical impedance analysis is a simple, non-invasive method of estimating total body water in neonates receiving intensive care. It can be applied to both the assessment of changes in body water and body composition.

OBESITY – Severe obesity is accompanied by large increases in fat mass and alterations in the composition of fat free mass, in particular total body water and its extra-cellular compartment.

OEDEMA – The Development of oedema after major abdominal surgery is associated with increased morbidity

PAEDIATRICS – Body composition in children is of increasing interest within the contexts of childhood obesity, clinical management of patients and nutritional programming as a pathway to adult disease.

PULMONARY OEDEMA – Impedance measurement may be useful in estimating lung water associated with lung injury following cardiopulmonary bypass.

REHABILITATION – Changes in body composition, as a consequence of dietary and exercise modification, contributed to the ''observed'' improvement noted in weight-adjusted peak aerobic capacity following cardiac rehabilitation and exercise training.

SEGMENTAL – There is increased use of segmental impedance in the assessment of diseases that affect body fluid balance.

SURGERY – The development of oedema after major abdominal surgery is associated with increased morbidity. Age and the reduced ability to excrete administered fluid load are significant aetlological factors and bioimpedance analysis can potentially identify patients at risk.

Who can benefit from using the QuadScan4000?

Diuretics, accurate fluid monitoring and the inevitable decrease of lean muscle mass are all concerns for patients, nurses and doctors alike.

Bioelectrical Impedance Technology will meet all these needs non-invasively, giving accurate and reliable measurements for fluid, lean muscle mass, nutritional status and overall cellular health.

Bioelectrical Impedance Technology has been used successfully in dialysis wards to measure the volume of fluid over-hydration to help determine dry weight, as well as in IC wards to assess nutritional status, recovery rate and hydration levels.

In addition, the QuadScan4000 may be used to detect malnutrition in patients with normal or high body fat. Body cell mass can easily be obscured by an expansion of extracellular fluid which will not be detected by looking at an overall increase in total body weight.

Segmental measures

Using the Prediction Marker (Impedance Ratio) you are able to monitor change in the condition of the body segment over a period of time.

Only the accurate raw Impedance measurement data at 5 kHz and 200 kHz is used to calculate the Prediction Marker (Impedance Ratio). So this is independent of regression equations and therefore does not require the subjects weight, height, gender or age.

However, the important point to remember is that it is CHANGE in the marker that should be focused upon to determine the TREND over a period of time, either hours, days, weeks or months.

The images below show the different types of electrode placements depending on the part of the body which requires measurement.

Segmental Measurement - Chest

Segmental Measurement - Hip

Segmental Measurement - Foot

Segmental Measurement - Hand

Segmental Measurement - Neck

Using your QuadScan 4000

Using your QuadScan4000 couldn't be easier – no training is required and the whole process is completely non-invasive, an important point for the patient. The QuadScan4000 has two main cable leads of which each lead has two crocodile/alligator clips, red and black. These clips are attached to the exposed tabs on the electrodes. The patients details are input using the simple keypad.

It works by passing a safe battery generated signal through the body and measuring the bioelectrical impedance at fixed frequencies of 5, 50, 100 and 200 kHz. Once the test has been performed a complete body composition analysis is displayed on the LCD screen within three seconds and comprehensive analysis can be printed.

Français Deutsch Español

Download Quadscan4000 Brochure Read Quadscan4000 Brochure Online
Brochure for Quadscan4000